Product
|
Pros |
Cons |
Features |
Application |
MSRP |
Trion SE 800E Smoke Eater  |
• Unique mounting options - can be ceiling-mounted, flush-mounted, or wall-mounted
• Supports fresh air return duct, if desired
|
• Must be hard-wired into electrical system
• More maintenance than a media-based smoke eater -Electronic filter cell must be washed periodically
|
• COANDA 360˚ airflow pattern creates an "envelope" of clean air.
• Aluminum mesh prefilter traps larger particles, allowing the electronic cells focus on the finer particulates
|
• Offices • Bars • Waiting Rooms • Smoking areas •Computer rooms |
Call for discount
(learn more about this Trion air cleaner)
|
AQE EverClear Smoke Eater  |
• Flush-mount design... only the attractive grille is visible
• Contains 9 lbs. activated carbon for odor removal
|
• Consumes slightly more energy to run than an electrostatic unit
• Contains filters that need to be replaced
|
• Can be fitted with a drop-skirt when full flush-mount is not possible
|
• Smoking lounges, clubs, and other places where space is a concern |
Call for discount |
AQE EverClear Deluxe Smoke Eater  |
• Flush-mount design only shows attractive grille
• Contains a whopping 44 lbs. activated carbon!
|
• Contains filters that need to be replaced
• Consumes slightly more energy to run than an electrostatic unit
|
• Can be fitted with a drop-skirt when full flush-mount is not possible
|
• Smoking lounges, clubs, and other places where space is a concern |
Call for discount |
AQE X-400 Smoke Eater
Read Review
|
• Main filters never require replacement.
• Inconspicuous - Grill fits flush with ceiling, cabinet hidden.
• COANDA Airflow pulls smoke up & distributes clean air.
• Includes odor controlling carbon.
|
• Requires periodic cleaning.
• Requires installation above ceiling.
• Only can handle one small enclosed room.
|
• Main Filter - Electrostatic Precipitator
• Post Filter - 2 Carbon Modules
• 3 Speeds
• Mounting brackets for standard 2'x2' ceiling tile.
|
• Home or small office where ceiling installation is possible.
• Up to about 500 sq ft room.
|
Call for discount
Read more about this home smoke air cleaner
|
AQE X11-Q SmokeMaster Smoke Eater  |
• Main filters never require replacement.
• Inconspicuous - Grill fits flush with ceiling, cabinet hidden.
• COANDA Airflow pulls smoke up & distributes clean air.
• Up to 1250 CFM
|
• Requires periodic cleaning.
• Requires installation above ceiling.
|
• Electrostatic cell plus two activated carbon filters for smoke and odor control
• 3 Speed fan
|
• Bars • Beauty solons • Pool halls • Bingo halls • Bowling centers • Conference Rooms • Break rooms • Hospitals • Offices • Photo/litho processors • Restaurants |
Call for discount
Research this electronic smoke eater air filter
|
Austin Air HealthMate Smoke Eater  |
• Low initial cost • Several pounds of carbon & Zeolite • True HEPA filtration |
• Only good for light smoke. • Only covers a very small room • Louder than most |
• True medical grade HEPA
• Granulated carbon/zeolite blend • 3 fan speeds
|
• Small enclosed room w/ one light smoker • Up to 200 sq. ft. |
Call for discount
more info
|
IQAir GC MultiGas Air Purifier Smoke Eater  |
• 12 lbs gas phase media
• High quality construction & design
• Requires little maintenance
• Handles a room up to 900 sq ft.
|
• Periodic filter replacement required |
• Custom gas, odor & smoke control
• Remote control
|
• Home, office, hospital, salon • Room up to about 900 sq ft. • Tobacco smoke, dust, pollen, pet dander, pollution, Acetic acid, Acetone, Acrolein, Acrylonitrile, 1.3 Butadiene, Butyric acid, Carbon disulfide, Chlorine dioxide, Cresol, Cyclohexanone, Diethylamine, Dimethylamine, Ethanol, Ethyl acetate, Ethyl acrylate, Ethylamine, Formic acid, Hydrogen chloride, Isoprene, Isopropanol, Methanol, Methyl acrylate, Methyl disulfide, Methyl ethyl ketone, Methyl mercaptan, Methyl sulfid, Methyl vinyl ketone, Methylamine, Nitroglycerine, Ozone, Phenol, Skatole, Styrene, Sulfur trioxide, Trichloroethylene, Tri hylamine, Trimethylamine, and Vinyl chloride |
Call for discount
Read more on this home & office air cleaner
|
IQAir HealthPro Plus Smoke Eater  |
• 5 lbs gas phase media
• High quality construction & design
• Requires little maintenance
• Handles a room up to 500 sq ft.
|
• Periodic filter replacement required |
• Custom gas, odor & smoke control |
• Home, office, hospital, salon • Room up to about 1200 sq ft. • Tobacco smoke, dust, pollen, pet dander, pollution, Acetic acid, Acetone, Acrolein, Acrylonitrile, 1.3 Butadiene, Butyric acid, Carbon disulfide, Chlorine dioxide, Cresol, Cyclohexanone, Diethylamine, Dimethylamine, Ethanol, Ethyl acetate, Ethyl acrylate, Ethylamine, Formic acid, Hydrogen chloride, Isoprene, Isopropanol, Methanol, Methyl acrylate, Methyl disulfide, Methyl ethyl ketone, Methyl mercaptan, Methyl sulfid, Methyl vinyl ketone, Methylamine, Nitroglycerine, Ozone, Phenol, Skatole, Styrene, Sulfur trioxide, Trichloroethylene, Tri hylamine, Trimethylamine, and Vinyl chloride |
Call for discount
Research this home smoke eater air cleaner
|
Trion CAC 500 Media Smoke Eater  |
• Main filters never require cleaning
• Low profile - Grille fits almost flush with ceiling, cabinet hidden
• COANDA Airflow pulls smoke up & distributes clean air
• Odor controlling carbon optional
|
• Requires periodic filter replacement
• Requires installation above ceiling
• Can only handle one small enclosed room
|
• Main Filter - Multi-pleat borosilicate glass fibers
• Post Filter - Optional Carbon
• 3 Speeds
• Mounts above standard 2'x2'ceiling tile or hangs below ceiling
|
• Home or small office where flush-mount ceiling installation is possible
• Up to about 500 sq ft room.
|
Call for discount
(read more about this light-duty smoke eater)
|
Trion CAC 1000 Electronic Smoke Eater
Read Review
|
• Washable electrostatic main filter cuts filter replacement cost to zero
• Hinged panel allows filter access without the use of tools
|
• More required maintenance involved than with media-based cigarette smoke eaters
• Higher initial investment
|
• Ultra-quiet fan at only 58 dbA on its highest setting
• Low Profile - only 3.8" exposed below ceiling level
|
• Small offices, home offices, break rooms up to 525 sq. ft. |
Call for discount
(read more about this light commercial air cleaner)
|
Trion FM 1000E Electronic Smoke Eater  |
• Above ceiling installation, fits into standard 2' x 4' ceiling tile
• Washable electrostatic filter cell
|
• Regular filter cell maintenance required to ensure optimal performance
• 19.63" deep -Requires considerable space above ceiling level
|
• 6-way air discharge, coanda airflow
• Can be modified for remote air discharge
|
• Restaurants • Bars • Taverns • Offices • Conference rooms • Break rooms |
Call for discount
(Learn more about this Trion smoke eater)
|
Trion FM 1000M Media Smoke Eater  |
• Main filter needs no scheduled cleaning
• Low profile, flush-mount design
|
• 19.63" deep -Requires considerable space above ceiling level
• Noticeably less airflow than its electrostatic counterpart
|
• 95% efficient per ASHRAE 52.1
• Remote on/off switch available
|
• Restaurants • Bars • Taverns • Offices • Conference rooms • Break rooms |
Call for discount
(Learn more about this Trion air cleaner)
|
Trion SE 400E Smoke Eater  |
• Unique mounting options - can be ceiling-mounted, flush-mounted, or wall-mounted
• Supports fresh air return duct, if desired
|
• Must be hard-wired into electrical system
• More maintenance than a media-based smoke eater -Electronic filter cell must be washed periodically
|
• Small footprint - designed to fit in a 2' x 2' ceiling grid
• COANDA 360˚ airflow pattern creates an "envelope" of clean air.
|
• Home offices • Small offices • Conference rooms • Break rooms |
Call for discount
(read more about this smoke eater)
|
UAS Smokeeter SE24 Smoke Eater  |
• No costly filters to replace
• Ceiling location is ideal for capturing rising smoke
• Mounts flush into space for standard 2'x4' ceiling panel
|
• Requires periodic maintenance |
• 3 speed control
• COANDA airflow sucks smoke up and blows clean air down
|
• Up to 1025 CFM will handle moderate smoke in a room up to about 564 sq ft
• Small to medium size break room, office, workshop, waiting room
|
Call for discount
Learn more about this smoke air purifier.
|
UAS Vision Air 1 Smoke Eater  |
• Versatile floor, wall, table or ceiling mount
• Looks great on stand or installed flush in the ceiling
• Optional Odor control
• UV option is ideal for smoke
• Carbon & odor control
|
• Requires periodic maintenance and/or replacement filters |
• Filter choice of either washable ESP or disposable media
• Optional air monitor automatically controls fan as needed
|
• ESP up to 750 CFM can handle heavy to moderate smoke in a room up to 415 sq ft
• Media up to 600 CFM can handle smoky room up to 306 sq ft
|
Call for discount
Learn more about this smoke air cleaner.
|
|
UAS Vision Air2 Smoke Eater
 |
• Looks great installed flush in the ceiling
• Optional Odor control
• UV option is ideal for smoke
• Carbon & odor control
|
• Requires periodic maintenance and/or replacement filters |
• Filter choice of either washable ESP or disposable media
• Optional air monitor automatically controls fan as needed
|
• ESP up to 1500 CFM can handle heavy to moderate smoke in a room up to 850 sq ft
• Media up to 1200 CFM can handle smoky room up to 625 sq ft
|
Call for discount
Research this smoke eater air cleaner.
|